Carrier Global Corporation
Lead Run Technician – Engineering Laboratory (2nd shift)
Carrier Global Corporation, Charlotte, North Carolina, United States, 28245
Carrier Global Corporation, global leader in intelligent climate and energy solutions, is committed to creating solutions that matter for people and our planet for generations to come. From the beginning, we've led in inventing new technologies and entirely new industries. Today, we continue to lead because we have a world‑class, diverse workforce that puts the customer at the center of everything we do. For more information, visit corporate.carrier.com or follow Carrier on social media at @Carrier.
About This Role Carrier is seeking an experienced and dependable Lead Technician in our engineering laboratories. This role is responsible for test execution, running the chillers in water‑cooled and air‑cooled labs. Individuals should be able to setup test environment, setup calibration and drive efficient chiller operation. The ideal candidate will have extensive experience in testing and troubleshooting water‑and‑air‑cooled commercial chillers, as well as maintaining a safe and efficient lab environment.
Key Responsibilities Chiller test operation at high efficiency:
Performs basic to moderately complex technical tasks which contribute to the planning and execution of engineering projects.
Operates, inspects and maintains chillers, test setups and equipment.
Should be able to work with electrical equipment, including 460‑3‑60 machinery, HVAC operation, refrigerant handling, and EPA certification.
Able to use/calibrate laboratory equipment to measure pressure, temperature, flow and electrical measurements.
Select, connect and troubleshoot electrical, mechanical and refrigeration systems on Charlotte manufactured equipment.
Able to do loop calibration, how to use valves for single / double loop configuration.
Operate/troubleshoot/calibrate, Power Management/VFD’s, boilers, valves configuration.
Should be able to coach team members, collaborate with cross‑functional teams and report out the results/issues to the relevant team to drive resolution.
Lab safety, maintenance and uptime:
Must be an advocate of safe workspace, 5S and champion the corporation's EHS policy.
Support lab uptime by reporting any instrument failures and enhancing preventive maintenance.
KPIs, Reporting, Transparency and Analytics:
Collects and reports test status, issue reporting.
Able to apply and teach measurement techniques, test report writing, systems troubleshooting.
Proactive in resolving testing hurdles by consulting development and other relevant process partners.
Required Qualifications
High School Diploma or GED.
5+ years experience in Chiller/HVAC operations, station and chiller and/or 5 years experience in a laboratory environment for mechanical/electrical machinery.
2+ years of experience independently leading/running chillers, reporting results, and in loop tuning and drive test cycle/loop efficiency.
5+ years of experience with hand/pneumatic tools, advanced shop mathematics, complex measuring equipment, precision measuring instruments.
Preferred Requirements
AS or AAS in related technical field.
Technical/Business School Certificate or Skilled Trades Apprenticeship.
Technical expert in HVAC design, components and ability to lead/run the chillers.
Understanding of closed‑loop control systems, loop stability.
Reading and interpreting complex drawings, schematics, and blueprints.
Experience with medium voltage operations, including arc flash and lockout/tagout procedures.
Work Environment
Hands‑on role requiring frequent standing, lifting (up to 50 lbs), climbing ladders, and working around moving mechanical equipment.
Exposure to temperature variations, refrigerants, compressed gases, and other lab‑specific conditions.
Occasional after‑hours or weekend work may be needed to support critical maintenance schedules.
Carrier is an Equal Opportunity/Affirmative Action Employer. All qualified applicants will receive consideration for employment without regard to race, color, religion, sex, sexual orientation, gender identity, national origin, disability or veteran status, age or any other federally protected class.
Job Applicant's Privacy Notice: Click on this to read the Job Applicant's Privacy Notice.
#J-18808-Ljbffr
About This Role Carrier is seeking an experienced and dependable Lead Technician in our engineering laboratories. This role is responsible for test execution, running the chillers in water‑cooled and air‑cooled labs. Individuals should be able to setup test environment, setup calibration and drive efficient chiller operation. The ideal candidate will have extensive experience in testing and troubleshooting water‑and‑air‑cooled commercial chillers, as well as maintaining a safe and efficient lab environment.
Key Responsibilities Chiller test operation at high efficiency:
Performs basic to moderately complex technical tasks which contribute to the planning and execution of engineering projects.
Operates, inspects and maintains chillers, test setups and equipment.
Should be able to work with electrical equipment, including 460‑3‑60 machinery, HVAC operation, refrigerant handling, and EPA certification.
Able to use/calibrate laboratory equipment to measure pressure, temperature, flow and electrical measurements.
Select, connect and troubleshoot electrical, mechanical and refrigeration systems on Charlotte manufactured equipment.
Able to do loop calibration, how to use valves for single / double loop configuration.
Operate/troubleshoot/calibrate, Power Management/VFD’s, boilers, valves configuration.
Should be able to coach team members, collaborate with cross‑functional teams and report out the results/issues to the relevant team to drive resolution.
Lab safety, maintenance and uptime:
Must be an advocate of safe workspace, 5S and champion the corporation's EHS policy.
Support lab uptime by reporting any instrument failures and enhancing preventive maintenance.
KPIs, Reporting, Transparency and Analytics:
Collects and reports test status, issue reporting.
Able to apply and teach measurement techniques, test report writing, systems troubleshooting.
Proactive in resolving testing hurdles by consulting development and other relevant process partners.
Required Qualifications
High School Diploma or GED.
5+ years experience in Chiller/HVAC operations, station and chiller and/or 5 years experience in a laboratory environment for mechanical/electrical machinery.
2+ years of experience independently leading/running chillers, reporting results, and in loop tuning and drive test cycle/loop efficiency.
5+ years of experience with hand/pneumatic tools, advanced shop mathematics, complex measuring equipment, precision measuring instruments.
Preferred Requirements
AS or AAS in related technical field.
Technical/Business School Certificate or Skilled Trades Apprenticeship.
Technical expert in HVAC design, components and ability to lead/run the chillers.
Understanding of closed‑loop control systems, loop stability.
Reading and interpreting complex drawings, schematics, and blueprints.
Experience with medium voltage operations, including arc flash and lockout/tagout procedures.
Work Environment
Hands‑on role requiring frequent standing, lifting (up to 50 lbs), climbing ladders, and working around moving mechanical equipment.
Exposure to temperature variations, refrigerants, compressed gases, and other lab‑specific conditions.
Occasional after‑hours or weekend work may be needed to support critical maintenance schedules.
Carrier is an Equal Opportunity/Affirmative Action Employer. All qualified applicants will receive consideration for employment without regard to race, color, religion, sex, sexual orientation, gender identity, national origin, disability or veteran status, age or any other federally protected class.
Job Applicant's Privacy Notice: Click on this to read the Job Applicant's Privacy Notice.
#J-18808-Ljbffr