Logo
KALCON

MEP QA/QC Manager (Data Center Construction)

KALCON, Fayetteville, Georgia, United States, 30215

Save Job

2 days ago Be among the first 25 applicants Get AI-powered advice on this job and more exclusive features. This range is provided by KALCON. Your actual pay will be based on your skills and experience — talk with your recruiter to learn more. Base pay range

$140,000.00/yr - $200,000.00/yr Direct message the job poster from KALCON The QA/QC Associate Role is a full-time onsite role (40-50 hours a week) that will be responsible for executing the General Contractor’s QC Program for various Data Hall Fit-out projects for the client in Fayetteville, GA. The fit-out projects are for various data halls with a limited scope when it comes to MEP equipment (LV Switchboard downstream to data hall busways.) The selected candidate will manage and execute the following tasks: • Perform Prep/Preconstruction and Initial Phase Meetings with our subcontractors. These meeting agendas will be created using the Procore software platform • Review all QC document deliverables from L1-L3 in the Cx Alloy software platform • Assist the MEP team with L2 equipment inspections (clean walks) • Issue Management- Record issues in Cx Alloy and ensure all issues are closed out by our subs/vendors in a timely manner. • Set up the project in Cx Alloy as needed- work with onsite MEP add checklist templates and have the subs add all their assets to the Program specific spreadsheet template. Then import into Cx Alloy. The selected candidate will be trained to perform this task if needed. • Create Feature of Work (FOW) Matrix based on work schedule. Note: A FOW is a project activity or a specification section. • Prepare documents in Procore for Preparatory Phase and Initial Phase meetings (review submittal register- AAN comments, JHA’s, FOW schedule and specification review) • Schedule and perform the Prep Meetings with our subs and invite all stakeholders. Add meeting notes to Procore and send them to attendees. • Schedule and execute the Initial Phase and fill out the checklist provided in Procore. • If necessary, perform receiving inspection with site superintendent and ensure that the sub provides all required paperwork and fills out the Cx Alloy equipment receiving checklists. • Review benchmarks and First of Kind (FOK) inspections and perform set-in-place inspections whether during the initial phase or soon after. Provide 1 weeks’ notice to the client at a minimum. • Inspection Phase- Confirm that the Installing Contractor fills out all the required L2 inspection checklists in Cx Alloy and track all inspection/test documentation and deliverables. These documented deliverables include (at minimum): o Pre-startup Reports o NETA Test Reports o Hydrostatic Test Reports (Mechanical) o Flushing Reports (Mechanical) o Point to Point • Ensure all L3 documentation (Start Up Reports) are provided • Assist MEP team with final L2/L3 document review and confirm completion and accuracy prior to L4 Commissioning. • Perform L2 HITT Pre-Energization Inspection and/or clean walks on equipment with the MEP team as needed. • Ensure all required labeling including Arc Flash Labels are placed prior to energization. • Perform routine examination and checks of the ongoing work and equipment placement to ensure quality installation. If necessary, record any issues in Cx Alloy. • Ensure that we are maintaining proper levels of protection during construction for equipment and systems. • Ensure that all open issues are properly routed to their respective assignees so that they can work to resolve the issues. • Address all issues in a timely manner. Allow 48 hours for closure. If past 48 hours provide justification along with a new due date every week thereafter until item is closed. Do NOT leave any open lingering issues. • Manage the Punch List Process with onsite team and perform weekly (or bi-weekly) status meetings with subs to resolve open items. • Physically confirm that all punch list items are corrected on the field. • Perform site walkthroughs at least 2 times a day and add any QC observations in the Cx Alloy issues tool. Lead/Manage all supers on the field to do the same. • OFCI Equipment QC Checks: If necessary, the QA/QC Associate will assist the HITT site ops/ops teams with managing OFCI equipment. The selected candidate will need to perform these duties: • Ensure POC for onsite equipment delivery contact info is up to date. • Ensure the site address for receiving equipment is correct. • Ensure equipment vendor has contacted site POC 2 weeks out and again 48 hours from date of shipment. • Notify Project Management/Senior Superintendent and OFCI Manager of equipment deliveries. Submission Requirements: At a minimum, the candidate’s professional resume must include the following: • List of all Educational Achievements • List of all Professional Licenses or Certificates • List of Awards Received • Detailed Employment History with each company, including: o Name & Contact Information of the firm or agency o Start Date and End Date (Month & Year) o Positions Held At KALCON we are committed to creating an inclusive, diverse, and equitable workplace where every individual is respected and valued. We are an equal opportunity employer, and all applicant and employees will receive consideration for employment as we do not tolerate discrimination of any kind based on race, color, religion, gender, sexual orientation, gender identity, national origin, age, disability, genetics, protected veteran status or any other protected characteristic as outlined by federal, state, or local laws. We believe that a diverse workforce contributes to the success of our company and the innovation behind the exceptional projects we deliver. We encourage and support applicants from all backgrounds, experiences, and perspectives to join our team and thrive. Our hiring and employment practices are guided by principles of fairness, equality, and opportunity for all. Seniority level

Seniority level Mid-Senior level Employment type

Employment type Full-time Job function

Job function Quality Assurance Industries Construction and Building Construction Referrals increase your chances of interviewing at KALCON by 2x Inferred from the description for this job

Medical insurance Vision insurance 401(k) Tuition assistance Get notified about new Quality Assurance Manager jobs in

Fayetteville, GA . Atlanta Metropolitan Area $90,000.00-$120,000.00 1 day ago Atlanta, GA $145,000.00-$160,000.00 2 days ago Assurance Manager, Quality Management - IS Assurance

Atlanta, GA $100,000.00-$150,000.00 3 days ago Atlanta, GA $118,000.00-$178,000.00 3 months ago Airline General Manager in Atlanta, GA (ATL)

Private Equity Center of Excellence, Manager

Atlanta, GA $93,000.00-$171,300.00 1 week ago Manager 2, Systems Development (Director of Technology & Innovation) - 00024137

Clinical Performance Improvement Manager (Must have Clinical Background and CMS/ TJC abstraction and reporting experience )

Assistant Quality Assurance Manager - Plant

Construction Quality Control Segment Manager

Administrative & Quality Assurance Manager

Traveling QC Manager - Mission Critical Construction

Atlanta, GA $140,000.00-$220,000.00 1 week ago Sr Quality Engineer - TestCafe & Selenium Grid - Remote

BSA AML and OFAC Compliance Function Manager II

Atlanta, GA $122,017.50-$166,149.00 1 week ago We’re unlocking community knowledge in a new way. Experts add insights directly into each article, started with the help of AI.

#J-18808-Ljbffr