Duties

(1) Calibrates and repairs TMDE within support capability and authority including various levels of calibration as designated in technical bulletins, manuals, etc. Performs functional electronic, physical, and radioactive testing involving interpretation and analysis of measurement data, in accordance with cyclic inspection requirements. Aligns, troubleshoots, tests, inspects, repairs, modifies, calibrates and certifies precision measurement equipment such as multimeters, microwave equipment, oscilloscopes, temperature analyzers, mercurial barometers, gauge blocks and micrometer caliper dimensional equipment, digital voltmeters, signal generators, torque wrenches, pressure gauges, torque testers, weight scales, electronic counters, radiation monitors, radix calibrators, and radiation dosimeters. Analyzes and isolates component malfunctions; calculates and determines tolerances; and performs tests and calibrations in accordance with instructions, which are often vague and incomplete, and may require the preparation of diagrams and instructions to facilitate the calibration action.

(2) Sets up system test sets and various types of test equipment such as frequency meters, standing wave ratio meters, radio frequency (RF) power meters, function/ arbitrary waveform generator, distortion analyzers, time frequency work stations, oscillators, voltmeters, electronic counters, oscilloscopes, attenuators, decade resistors and capacitors, signal generators, stroboscope, tachometers, pneumatic and hydraulic pressure standards and other physical and electronic tests. Diagnoses equipment, makes repairs, and replaces defective parts/components such as integrated circuits, printed circuit boards, electronic condition coils, radiation detector boards/circuits, crystals, transistors, tubes, transformers, condensers, diodes, relays potentiometers, and related components.

(3) Following repair, tests by applying signals in known amplitude and wave shape into oscilloscopes to observe wave pattern. Isolates faults by taking measurements and comparisons in voltage, amperage, ohms, henries, power factor, watts, temperature, humidity, microns, foot-pounds, decibels, sensitivity, noise, stability, Voltage Standard Wave Ratio (VSWR), impedance, phase, absolute pressure, time intervals, displacement, flow rate, etc., to determine performance of equipment. If signal is distorted, traces it through electronic stages to locate malfunctioning part. Checks sweep rate by feeding known signal to an oscilloscope and observing wave pattern to correct shape and size. Operates equipment to complete range checking for proper operation of positioning controls. Adjusts with trimmer potentiometers; and if calibration is still not possible, adds or removes sufficient resistance to permit balancing of circuit. As needed, contacts the using organization to obtain information concerning the nature of the malfunction. Uses equipment schematics to analyze circuits by preparing block diagram showing major components such as amplifiers, filters, oscillators and indicators.

(4) Determines purpose in operation characteristics of each major section. Refers to technical manuals and manufacturers specifications to obtain information on operation characteristics of circuit components such as integrated circuits, microprocessors, decoders, latching networks, notch filters, logics, controllers, programmable gain amplifiers, digital displays, transistors, tubes, transformers, coils, relays, motors, and similar devices. Disassembles, cleans and inspects parts such as printed circuit boards, resistors, capacitors, integrated circuits, relays, chambers, cables, and wiring for evidence or wear or malfunction. Repairs and/or replaces parts as required. Uses special test devices and radioactive samples or other calibrated sources. Tests equipment for sensitivity and correct operation. Observes necessary precautions as stipulated in operational repair manuals. Makes radiation calculations/readings at various distances from the standard ensuring radiation equipment is operating in specified parameters. Performs contamination/radiation surveys on radiation equipment to control/eliminate radiation leakage/contamination.

DUTIES CONTINUED UNDER EDUCATION

Requirements NATIONAL GUARD MEMBERSHIP IS REQUIRED.

If you are not sure you are eligible for military membership, please contact a National Guard recruiter prior to applying for this position.

Compatible military grade and assignment required prior to the effective date of placement. This is an excepted service position that requires membership in a compatible military assignment in the employing state's National Guard. Applicants who are not currently a member of the National Guard must be eligible for immediate membership in the military grade listed below. Selectee will be required to wear the military uniform.

Military Grades:

Enlisted

Minimum Grade - PVT (E-1)

Maximum Grade - SFC (E-7)

Compatible Military Assignments:

Selectee must be a member of the Arkansas Army National Guard.

IMPORTANT NOTES (AS APPLICABLE):

Upon selection for this position, individual must possess or initiate a National Agency Check with Inquiries (NACI) background investigation. A favorable determination based upon investigative results is mandatory for this position. Failure to meet these requirements will result in termination of employment. A pre-placement physical is required if not already current. Upon selection, must complete mandatory Full-Time Support (FTS) Training at the Professional Education Center (PEC) within six months of assignment (if applicable, training will be coordinated by the supervisor). Individual must meet all military requirements of the position without creating a grade inversion, as determined by the Human Resources Office (HRO). Technicians will not be militarily senior to their full-time supervisor or wage leader (Grade Inversion). Enlisted members currently at a higher grade than allowed by the position (see Military Grade Requirement above) may apply; however, they must administratively reduce prior to appointment and provide confirmation of the reduction to HRO.

Additional Requirements ADDITIONAL REQUIREMENTS ARE LISTED UNDER ADDITIONAL INFORMATION

#J-18808-Ljbffr